Part Number Hot Search : 
OP200GPZ AN1042 P8051 SP322CF FX009LG M66240FP B120K U1001
Product Description
Full Text Search
 

To Download AMEO6-NZ13 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  series am eo6 -nz 6 w att | a c - dc / dc- dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r8 .a 1 of 3 north america only features: models single output model input voltage (vac/hz) inpu t voltage (vdc) temperature range (oc) output voltage (v) output current max (a) maximum capacitive load ( f ) efficiency (%) am e o 6 - 5s - nz 30 - 280 / 47 - 440 30 - 400 - 25 to +70 5 1.2 6000 7 1 ameo6 - 12 s - nz 30 - 280 / 47 - 440 30 - 400 - 25 to +70 12 0.55 2000 77 no te: all specifications in this datasheet are measured at an ambient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. i nput specifications parameters conditions typical maximum units current vin =220vac 100 ma inrush current <2ms vin=220vac 20 a vin=110vac 10 leakage current vin=2 3 0vac , 50hz 0.3 ma external fuse slow blow type 3.15a 250v a input d issipation vin=220vac, io=0a 0.55 w output specifications parameters conditions typical maximum units voltage accuracy 1 % line regulation 0.5 % load regulation 10 C 100% of load 1 % transient recovery time 500 s for 25% load step 1000 s transient response deviation 4 mv % ripple & noise 20mhz bandwidth (5v model) 75 ( 12 v model) 130 mv p -p hold - up time (min) 200 ms isolation specifications parameters conditions typical rated units tested i/o voltage 60s > 50m? 4000 v ac general specifications parameters conditions typical maximum units switching frequency 6 0 khz start up time 50 ms over voltage protection clamp diode % short circuit protection continuous short c ircuit restart a uto recovery operating temperature refer to derating curve - 25 to +70 o c storage temperature - 25 to +85 o c cooling free air convection temperature coefficient 0.02 % / o c humidity 20 - 90 % rh weight 55 g dimensions (l x w x h) 3.1 4 (l) x 1. 5 7 (w) x 1 .81 (h) inches 8 0 (l) x 40 (w) x 30 (h) mm mtbf > 300,000h @25c ? open frame design ? very wide input range ? 4000 vac isolation ? low ripple & noise ? short circuit protection ? high efficiency ? over - voltage p rotection ? low standby power < 0. 55 w
series am eo6 -nz 6 w att | a c - dc / dc- dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r8 .a 2 of 3 north america only environment approval test parameters conditions shock acceleration amplitude 196.1 m/s2 bump duration 11 ms number of bumps along x, y, z, once each vibration test mode 10 ~ 5 5 hz displacement 3 minutes / cycle acceleration 19.6 m/s2 converter operation 60 minutes safety specifications parameters standards designed to meet : iec en61000 - 4 - 2, en61000 - 4 - 3, en61000 - 4 - 4, iec en61000 - 4 - 5, en61000 - 4 - 6, en61000 - 4 - 8, en61000 - 4 - 11, en 55022 class b pin out specifications typical application s it is recommended that the output adds tvs (transient voltage suppressor) to protect adjacent circuits (if device fails ). derating - 20 0 20 40 60 80 100 100 80 60 40 20 0 55 o c safe operating area - 25 free air convection ambient temperature o c output power % 55 -10 pin designation 1 ac input ( l ) 2 ac input ( n ) 3 nc 4 no pin 5 common 6 +v output device value c1 electrolytic 100 f / 25 v c2 ceramic 0.1 f / 50v tvs p6smb7.5a (ameo6 - 5s - nz) p6smb16a (ameo6 - 12s - nz) + + - vo 1 l n l n c 1 c 2 tvs rl fuse
series am eo6 -nz 6 w att | a c - dc / dc- dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r8 .a 3 of 3 north america only dimensi ons 1 2 3 4 5 6 2 0.15 dimensions mm (inch) 15 (0.59) 32 (1.26) 8.5 (0.33) 4 (0.15) 74 (2.91) 80 1 (3.14 0.04 ) 3 (0.12) 32 (1.26) 40 1 (1.57 0.04 ) 2.5 0.15 (0.10 0.006 ) 1.5 0.15 (0.06 0.006 ) 4.8 (0.19) 4.8 (0.19) 1.6 (0.06) 0.5 (0.02) 1.2 (0.05) 30 (1.18) max 74 (2.91) 80 1 (3.14 0.04 ) note: 1. datasheets are updated as needed and as such, specifications are subject to change without notice. once printed or downloaded, datasheets are no longer controlled by aimtec; refer to www.aimtec.com for the most current product specifications. 2. product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. mechanical drawings and specifications are for reference only. 4 . all specifications are measured at an ambient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specifie d. 5. aimtec may not hav e conducted destructive testing or chemical analysis on all internal components and chemicals at the ti me of publishing this document. cas numbers and other limited information are considered proprietary and may not be available for release. 6. this product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet . 7. warranty is in accordance with aimtecs standard terms of sale available at www.aimtec.com .


▲Up To Search▲   

 
Price & Availability of AMEO6-NZ13

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X